Synchrotron/Neutron/Fusion » Synchrotron » Motion System for KB Mirror
Motion System for KB Mirror

A system was designed for Argonne National Laboratory that provides 5 degrees of motion for their KB Mirror.  The mirror chamber has 50 mm of vertical (z-axis) travel and 75 mm horizontal (x-axis) travel with a resolution of 1 µm.  Through the use of stacked precision slides, precision jacks, and free slides the chamber can also be rotated around the x-axis, y-axis, and z-axis to allow for leveling and alignment of the chamber.  The motion system sits on a granite base providing stability and vibration dampening.  The granite is leveled precisely with lockable leveling feet and bolted to an aluminum plate grouted to the floor. 

 

 

Key Specifications:

 

            Linear Travel Specifications:

 

Description

Value

Units

Range of Motion (Z Axis)

50 [~2]

mm [in]

Resolution (unit/step)

~0.001

mm/step

Encoder Manuf.

Renishaw

-

Encoder Resolution

0.1

µm

 

Description

Value

Units

Range of Motion (X Axis)

75 [~3]

mm [in]

Resolution (unit/step)

~0.001

mm/step

Encoder Manuf.

Renishaw

-

Encoder Resolution

0.1

μm

 